Skip to content

Bicarbonate · compensation · anion gap

← All Traditional guides

Anion gap and delta analysis

Use albumin correction and a declared reference before interpreting the relationship between the gap and bicarbonate.

Calculate a consistent anion gap

AG = Na⁺ − Cl⁻ − HCO₃⁻
Corrected AG = AG + 0.25 × [40 − albumin (g/L)]

Potassium is excluded throughout this app. Sodium, chloride and bicarbonate should represent a compatible set of measurements. When available, contemporaneous chemistry total CO₂ is used for the chemistry-based gap; gas-derived bicarbonate is labelled as an estimate.

The RCPA no-potassium reference is 4–13 mmol/L. A local method-matched interval takes priority. The default delta anchor of 8.5 is the midpoint of 4–13, not a measured personal baseline or a published population mean.

Correct for albumin when it is measured

Lower albumin reduces the baseline contribution to the gap. Correction makes this effect visible without pretending to identify the remaining anions. With albumin in g/dL, the correction coefficient is 2.5 instead of 0.25.

AG 12.5; albumin 20 g/L

Corrected AG = 12.5 + 0.25 × (40 − 20) = 17.5 mmol/L. The raw result is inside 4–13; the corrected result is above it.

Open worked example

If albumin is missing, show the uncorrected AG and state that correction is unavailable. Do not substitute a normal albumin.

Compare the gap rise with the bicarbonate fall

ΔAG = corrected AG − selected AG anchor
ΔHCO₃⁻ = 24 − HCO₃⁻
Delta ratio = ΔAG / ΔHCO₃⁻
Delta-adjusted HCO₃⁻ = HCO₃⁻ + ΔAG
A screening interpretation for established high-gap metabolic acidosis
Delta ratioQuestion to investigate
Below 1Is there an additional normal-gap metabolic acidosis?
1 to 2The pattern is compatible with high-gap acidosis without a second metabolic process being established.
Above 2Is metabolic alkalosis present, or was bicarbonate already raised before this illness?

These are interpretive prompts. The relationship varies with the underlying disorder, timing, renal handling, fluids and the chosen baseline; the ratio cannot prove a mixed disorder by itself.

When a delta ratio is not useful
  • The gap is not established as high, albumin correction is unavailable, or the primary process remains uncertain.
  • Bicarbonate is not reduced: a zero denominator cannot produce a ratio. A small denominator makes the ratio unstable.
  • Gas and chemistry samples are incompatible in time or show an unresolved discrepancy.
  • A respiratory disorder already explains the bicarbonate change.

The app restricts ratio interpretation to a confirmed high-gap pattern with bicarbonate below 22 mmol/L and compatible measurements. Delta-adjusted bicarbonate may still be informative when a raised gap coexists with a near-normal gas; it remains a screen.

Sources

RCPA Manual — Anion gap · Figge et al. — Anion gap and hypoalbuminaemia (1998) · American Thoracic Society — Interpretation of arterial blood gases · Paulson & Gadallah — Mixed disorders in diabetic ketoacidosis (1993) · Wrenn — The delta gap and mixed disorders (1990)

Adult educational interpretation at 37°C. Apply arterial rules to arterial samples, use the laboratory’s reference intervals, and review the result alongside the clinical history.

Use on your phone or offline

Add to Home Screen

Open your browser menu and choose Install app or Add to Home Screen.

Save for offline

Save the calculator and reference pages on this device. Entered results are not included or automatically saved.

Checking this device…

After saving, reopen the app from your Home Screen in airplane mode to check it works. Your browser may remove offline files when storage is low. The medical disclaimer and terms also apply to installed and offline copies.

Prefer a downloadable HTML file?